Pathology and Laboratory Medicine HomeTest and Services CatalogueTransfusion Medicine Product CataloguePolicy and ProcedureJob AidsSpecimen Collection and TransportRequisitionsAntibiogramsGenetic Testing and Molecular GeneticsMicrobiology EssentialsTransfusion EssentialsReference RangesLaboratory SuppliesAcute Care SCM GuidelinesContact InformationPhysician Access to Patient ResultsOpening A New Clinic
Pathology and Laboratory Medicine
Test Catalogue

Blood Gases, Venous - Cord Blood

Chemistry

​​Specimen Requirements​

Type​
  • ​Whole blood
​Container
  • ​Preferred Collection Container: Syringe (calcium and electrolyte balanced)
​Collection Procedure
  • Blood must be collected from a vein
  • Air bubbles must be removed
  • Sample contents in the syringe must be mixed to avoid clotting 
​Required Volume
  • ​Optimal Volume: 1 ml
  • Pediatric Volume: 0.5 mL
    (Submitting the minimum volume makes it impossible to repeat the test or perform confirmatory/reflex testing. In some situations, a minimum volume may require a second collection.)
​Stability/ Storage
  • ​1 hour post collection - Delayed analysis increases the risk that test results no longer represent patient status
​Grounds for Rejection

Testing Information​ ​

Availability​
  • ​24 hours a day
Testing Site​
  • RUH
Results Reporting​
  • ​Within 15 minutes of receipt in laboratory
​Methodology
  • ​Amperometric assay
​Specimen Retention
  • Specimens are discarded immediately after testing
SHR LIS Test Code​
  • ​BGVC (For Laboratory Use Only)

​​ 