PatientsVisitorsLocations & ServicesAbout the RegionJoin Our TeamPhysicians
Find:  Locations | Services
Pathology and Laboratory Medicine HomeTest and Services CatalogueTransfusion Medicine Product CataloguePolicy and ProcedureJob AidsSpecimen Collection and TransportRequisitionsAntibiogramsGenetic Testing and Molecular GeneticsMicrobiology EssentialsTransfusion EssentialsReference RangesLaboratory SuppliesAcute Care SCM GuidelinesContact InformationPhysician Access to Patient ResultsNew Clinic or Provider Information Changes
Pathology and Laboratory Medicine
Test Catalogue

​Factor 9 (IX) Inhibitor Level

Hematology - Special Coagulation


​Ordering Recommendation

  • ​​Patient should not be on any anticoagulant
  • If unable to discontinue anticoagulant therapy, suggest consultation with hematopathologist prior to ordering

Specimen Requirements​ ​

Type​
  • ​Whole blood
​Container
​Collection Procedure
​Required Volume
​Stability/Storage
  • ​Whole blood specimen shall be received at RUH Coagulation Laboratory within 2 hours of collection
  • Specimen is discarded after reporting
  • If an extra specimen is collected it is retained for 3 months.
Grounds for Rejection​
  • ​Line draws
  • Hemolyzed
  • Clotted
  • Inappropriately filled tubes
  • Patient on anticoagulant therapy testing must be approved by the Hematopathologist on service
  • Frozen aliquot specimen shipped without dry ice
  • Plasma specimen that has thawed and been refrozen
  • Plasma specimen that has thawed for more than 2 hours
  • Pathology and Laboratory Medicine Acceptance and Rejection Criteria   

Testing Information​ ​

Availability​
  • ​Monday to Friday 07:30 – 16:00 excluding statutory holidays unless approved by the hematopathologist on call
Testing Site​
  • ​RUH Special Coagulation Laboratory
Results Reporting​
  • ​Specimens are batched and performed once per week
Alternate Test Names​
  • ​F9 Inhibitor
SHR LIS Test Code​
  • F9IN (For Laboratory Use Only)


​If you choose to print this information, it is valid only on date of print.

Laboratory Controlled Document LSM-277 v2

Last Modified: Friday, September 29, 2017 |
Questions or feedback about this page?